submit url add directory Physician Assistant jobs ♦ Nurse Practitioner jobs
Related Topics:
RadiologyMagnetic Resonance Imaging :: Nuclear Magnetic Resonance
MRI :: Medical Physics
Today's News:
pubmed: 0730-725X
Optimal real-time estimation in diffusion tensor imaging.
Casaseca-de-la-Higuera P, Tristán-Vega A, Aja-Fernández S, Alberola-López C, Westin CF, San José Estépar R Optimal real-time estimation in diffusion tensor imaging. Magn Reson Imaging. 2012 Feb 1; Authors: Casaseca-de-la-Higuera P, Tristán-Vega A, Aja-Fernández S, Alberola-López C, Westin CF, San José Estépar R Abstract Diffusion tensor imaging (DTI) constitutes the most used paradigm among the diffusion-weighted magnetic resonance imaging (DW-MRI) techniques due to its simplicity and application potential. Recently, real-time estimation in DW-MRI has deserved special attention, with several proposals aiming at the estimation of meaningful diffusion parameters during the repetition time of the acquisition sequence. Specifically focusing on DTI, the underlying model of the noise present in the acquired data is not taken into account, leading to a suboptimal estimation of the diffusion tensor. In this paper, we propose an optimal real-time estimation framework for DTI reconstruction in single-coil acquisitions. By including an online estimation of the time-changing noise variance associated to the acquisition process, the proposed method achieves the sequential best linear unbiased estimator. Results on both synthetic and real data show that our method outperforms those so far proposed, reaching the best performance of the existing proposals by processing a substantially lower number of diffusion images. PMID: 22305020 [PubMed - as supplied by publisher]
Signal evolution in the local magnetic field of a capillary - analogy to the damped driven harmonic oscillator.
Ziener CH, Kampf T, Melkus G, Jakob PM, Schlemmer HP, Bauer WR Signal evolution in the local magnetic field of a capillary - analogy to the damped driven harmonic oscillator. Magn Reson Imaging. 2012 Feb 1; Authors: Ziener CH, Kampf T, Melkus G, Jakob PM, Schlemmer HP, Bauer WR Abstract The temporal behavior of the magnetization decay caused by the local inhomogeneous magnetic field of a capillary is analyzed. Respecting the diffusion of the spins surrounding the capillary and the strength of the susceptibility difference between the capillary and the surrounding medium, it is possible to distinguish different dephasing regimes. Each dephasing regime can be related to a certain characteristic form of the magnetization decay. If the influence of the diffusion dominates, the magnetization exhibits a monotonic decay. In the opposite case of dominating influence of the susceptibility effects, the magnetization shows an oscillating behavior. It can be shown that the dephasing process is closely related to the behavior of a damped driven harmonic oscillator. PMID: 22305019 [PubMed - as supplied by publisher]
Magnetic Resonance Materials in Physics, Biology and Medicine (Online Firstâ„¢)
Minimization of spectral pattern changes during HRMAS experiments at 37 degrees celsius by prior focused microwave irradiation
Sat, 28 Jan 2012 16:50:48 -0000
Abstract Object High-resolution magic angle spinning (HRMAS) magnetic resonance spectroscopy provides detailed metabolomic information from intact tissue. However, long acquisition times and high rotation speed may lead to time-dependent spectral pattern changes, which may affect proper interpretation of results. We report a strategy to minimize those changes, even at physiological recording temperature. Materials and methods Glioblastoma (Gbm) tumours were induced in 12 mice by stereotactic injection of GL261 cells. Animals were sacrificed and tumours were removed and stored in liquid N2. Half of the samples were exposed to focused microwave (FMW) irradiation prior to HRMAS while the other half was not. Time-course experiments (374 min at 37°C, 9.4T, 3,000 Hz spinning rate) were carried out to monitor spectral pattern changes. Differences were assessed with Unianova test while post-HRMAS histopathology analysis was performed to assess tissue integrity. Results Significant changes (up to 1.7 fold) were observed in samples without FMW irradiation in several spectral regions e.g. mobile lipids/lactate (0.90–1.30 ppm), acetate (1.90 ppm), N-acetyl aspartate (2.00 ppm), and Choline-containing compounds (3.19–3.25 ppm). No significant changes in the spectral pattern of FMW-irradiated samples were recorded. Conclusion We describe here a successful strategy to minimize spectral pattern changes in mouse Gbm samples using a FMW irradiation system. Content Type Journal ArticleCategory Research ArticlePages 1-10DOI 10.1007/s10334-012-0303-1Authors Myriam Davila, Departament de BioquÃmica i Biologia Molecular, Unitat de BioquÃmica de Biociències, Edifici Cs, Universitat Autònoma de Barcelona, 08193 Cerdanyola del Vallès, SpainAna Paula Candiota, Departament de BioquÃmica i Biologia Molecular, Unitat de BioquÃmica de Biociències, Edifici Cs, Universitat Autònoma de Barcelona, 08193 Cerdanyola del Vallès, SpainMartà Pumarola, Murine Pathology Unit, Centre de Biotecnologia Animal i Terà pia Gènica (CBATEG), Universitat Autònoma de Barcelona, 08193 Cerdanyola del Vallès, SpainCarles Arus, Departament de BioquÃmica i Biologia Molecular, Unitat de BioquÃmica de Biociències, Edifici Cs, Universitat Autònoma de Barcelona, 08193 Cerdanyola del Vallès, Spain Journal Magnetic Resonance Materials in Physics, Biology and MedicineOnline ISSN 1352-8661Print ISSN 0968-5243
MR perfusion imaging by alternate slab width inversion recovery arterial spin labeling (AIRASL): a technique with higher signal-to-noise ratio at 3.0 T
Fri, 13 Jan 2012 17:15:50 -0000
Abstract Object To propose a new arterial spin labeling (ASL) perfusion-imaging method (alternate slab width inversion recovery ASL: AIRASL) that takes advantage of the qualities of 3.0 T. Materials and methods AIRASL utilizes alternate slab width IR pulses for labeling blood to obtain a higher signal-to-noise ratio (SNR). Numerical simulations were used to evaluate perfusion signals. In vivo studies were performed to show the feasibility of AIRASL on five healthy subjects. We performed a statistical analysis of the differences in perfusion SNR measurements between flow-sensitive alternating inversion recovery (FAIR) and AIRASL. Results In signal simulation, the signal obtained by AIRASL at 3.0 and 1.5 T was 1.14 and 0.85%, respectively, whereas the signal obtained by FAIR at 3.0 and 1.5 T was 0.57 and 0.47%, respectively. In an in vivo study, the SNR of FAIR (3.0 T) and FAIR (1.5 T) were 1.73 ± 0.49 and 1.02 ± 0.20, respectively, whereas the SNRs of AIRASL (3.0 T) and AIRASL (1.5 T) were 3.93 ± 1.65 and 1.34 ± 0.31, respectively. SNR in AIRASL at 3.0 T was significantly greater than that in FAIR at 3.0 T. Conclusion The most significant potential advantage of AIRASL is its high SNR, which takes advantage of the qualities of 3.0 T. This sequence can be easily applied in the clinical setting and will enable ASL to become more relevant for clinical application. Content Type Journal ArticleCategory Research ArticlePages 1-9DOI 10.1007/s10334-011-0301-8Authors Yasuhiro Fujiwara, Radiological Center, University of Fukui Hospital, Fukui, JapanHirohiko Kimura, Department of Radiology, Faculty of Medical Science, University of Fukui, 23-3, Shimoaizuki, Matsuoka, Eiheiji-tyo, Yoshida-gun, Fukui, 910-1193 JapanTosiaki Miyati, Division of Health Sciences, Kanazawa University Graduate School of Medical Science, Kanazawa, JapanHiroyuki Kabasawa, Applied Science Laboratory Japan, GE Healthcare Japan Corporation, Tokyo, JapanTsuyoshi Matsuda, Advanced Application Center, GE Healthcare Japan Corporation, Tokyo, JapanYoshiyuki Ishimori, Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, Ibaraki, JapanIsao Yamaguchi, Department of Radiological Technology, Osaka Butsuryo College, Osaka, JapanToshiki Adachi, Radiological Center, University of Fukui Hospital, Fukui, Japan Journal Magnetic Resonance Materials in Physics, Biology and MedicineOnline ISSN 1352-8661Print ISSN 0968-5243
Repeatability of renal arterial spin labelling MRI in healthy subjects
Fri, 13 Jan 2012 17:15:46 -0000
Abstract Object Arterial spin labelling (ASL) can be used to measure renal perfusion non-invasively. The aim of this study was to determine the repeatability of this technique in healthy kidneys to vindicate its use in clinic. Materials and methods Two groups of healthy volunteers were imaged two different days to assess intra- and inter-session repeatability. Oblique-coronal data volumes were acquired on a 1.5 T scanner with a dedicated abdominal 32-channel body phased array coil. ASL was performed using a multi-TI FAIR labelling scheme and 3D GRASE imaging module. Background suppression and respiratory triggering were used. T1 maps of the kidney were acquired using the same sequence with background suppression disabled. Results For the group with multiple intra-session ASL measurements, the average cortical perfusion was 197 mL min−1100 g−1 and average cortical T1 was 1265 ms. For both perfusion and T1 the variation shown by the within-subject standard deviation (SDws) (14.6 mL min−1100 g−1 and 33.4 ms) and coefficient of variation (CVws) (7.52 and 2.69%, respectively) was small for all the analyses carried out. Bland–Altman plots were also used to visualise the variation between the same parameters collected from the different scanning sessions in both groups, and demonstrated good reproducibility. Conclusion We have shown that in healthy volunteers, ASL parameters are repeatable over a short and long period. This supports the overall aim of using ASL in the clinic to assess longitudinal renal perfusion changes in patients. Content Type Journal ArticleCategory Research ArticlePages 1-9DOI 10.1007/s10334-011-0300-9Authors Marica Cutajar, Imaging and Biophysics Unit, UCL Institute of Child Health, 30 Guilford Street, London, WC1N 1EH UKDavid L. Thomas, Department of Brain Repair and Rehabilitation, UCL Institute of Neurology, Queen Square, London, WC1N 3BG UKTina Banks, Department of Radiology, Great Ormond Street Hospital, London, WC1N 3JH UKChristopher A. Clark, Imaging and Biophysics Unit, UCL Institute of Child Health, 30 Guilford Street, London, WC1N 1EH UKXavier Golay, Department of Brain Repair and Rehabilitation, UCL Institute of Neurology, Queen Square, London, WC1N 3BG UKIsky Gordon, Imaging and Biophysics Unit, UCL Institute of Child Health, 30 Guilford Street, London, WC1N 1EH UK Journal Magnetic Resonance Materials in Physics, Biology and MedicineOnline ISSN 1352-8661Print ISSN 0968-5243
Subscribe to Magnetic_Resonance_Imaging RSS feed 
Optimal real-time estimation in diffusion tensor imaging.
Casaseca-de-la-Higuera P, Tristán-Vega A, Aja-Fernández S, Alberola-López C, Westin CF, San José Estépar R Optimal real-time estimation in diffusion tensor imaging. Magn Reson Imaging. 2012 Feb 1; Authors: Casaseca-de-la-Higuera P, Tristán-Vega A, Aja-Fernández S, Alberola-López C, Westin CF, San José Estépar R Abstract Diffusion tensor imaging (DTI) constitutes the most used paradigm among the diffusion-weighted magnetic resonance imaging (DW-MRI) techniques due to its simplicity and application potential. Recently, real-time estimation in DW-MRI has deserved special attention, with several proposals aiming at the estimation of meaningful diffusion parameters during the repetition time of the acquisition sequence. Specifically focusing on DTI, the underlying model of the noise present in the acquired data is not taken into account, leading to a suboptimal estimation of the diffusion tensor. In this paper, we propose an optimal real-time estimation framework for DTI reconstruction in single-coil acquisitions. By including an online estimation of the time-changing noise variance associated to the acquisition process, the proposed method achieves the sequential best linear unbiased estimator. Results on both synthetic and real data show that our method outperforms those so far proposed, reaching the best performance of the existing proposals by processing a substantially lower number of diffusion images. PMID: 22305020 [PubMed - as supplied by publisher]
Signal evolution in the local magnetic field of a capillary - analogy to the damped driven harmonic oscillator.
Ziener CH, Kampf T, Melkus G, Jakob PM, Schlemmer HP, Bauer WR Signal evolution in the local magnetic field of a capillary - analogy to the damped driven harmonic oscillator. Magn Reson Imaging. 2012 Feb 1; Authors: Ziener CH, Kampf T, Melkus G, Jakob PM, Schlemmer HP, Bauer WR Abstract The temporal behavior of the magnetization decay caused by the local inhomogeneous magnetic field of a capillary is analyzed. Respecting the diffusion of the spins surrounding the capillary and the strength of the susceptibility difference between the capillary and the surrounding medium, it is possible to distinguish different dephasing regimes. Each dephasing regime can be related to a certain characteristic form of the magnetization decay. If the influence of the diffusion dominates, the magnetization exhibits a monotonic decay. In the opposite case of dominating influence of the susceptibility effects, the magnetization shows an oscillating behavior. It can be shown that the dephasing process is closely related to the behavior of a damped driven harmonic oscillator. PMID: 22305019 [PubMed - as supplied by publisher]
Magnetic Resonance Materials in Physics, Biology and Medicine (Online Firstâ„¢)
Minimization of spectral pattern changes during HRMAS experiments at 37 degrees celsius by prior focused microwave irradiation
Sat, 28 Jan 2012 16:50:48 -0000
Abstract Object High-resolution magic angle spinning (HRMAS) magnetic resonance spectroscopy provides detailed metabolomic information from intact tissue. However, long acquisition times and high rotation speed may lead to time-dependent spectral pattern changes, which may affect proper interpretation of results. We report a strategy to minimize those changes, even at physiological recording temperature. Materials and methods Glioblastoma (Gbm) tumours were induced in 12 mice by stereotactic injection of GL261 cells. Animals were sacrificed and tumours were removed and stored in liquid N2. Half of the samples were exposed to focused microwave (FMW) irradiation prior to HRMAS while the other half was not. Time-course experiments (374 min at 37°C, 9.4T, 3,000 Hz spinning rate) were carried out to monitor spectral pattern changes. Differences were assessed with Unianova test while post-HRMAS histopathology analysis was performed to assess tissue integrity. Results Significant changes (up to 1.7 fold) were observed in samples without FMW irradiation in several spectral regions e.g. mobile lipids/lactate (0.90–1.30 ppm), acetate (1.90 ppm), N-acetyl aspartate (2.00 ppm), and Choline-containing compounds (3.19–3.25 ppm). No significant changes in the spectral pattern of FMW-irradiated samples were recorded. Conclusion We describe here a successful strategy to minimize spectral pattern changes in mouse Gbm samples using a FMW irradiation system. Content Type Journal ArticleCategory Research ArticlePages 1-10DOI 10.1007/s10334-012-0303-1Authors Myriam Davila, Departament de BioquÃmica i Biologia Molecular, Unitat de BioquÃmica de Biociències, Edifici Cs, Universitat Autònoma de Barcelona, 08193 Cerdanyola del Vallès, SpainAna Paula Candiota, Departament de BioquÃmica i Biologia Molecular, Unitat de BioquÃmica de Biociències, Edifici Cs, Universitat Autònoma de Barcelona, 08193 Cerdanyola del Vallès, SpainMartà Pumarola, Murine Pathology Unit, Centre de Biotecnologia Animal i Terà pia Gènica (CBATEG), Universitat Autònoma de Barcelona, 08193 Cerdanyola del Vallès, SpainCarles Arus, Departament de BioquÃmica i Biologia Molecular, Unitat de BioquÃmica de Biociències, Edifici Cs, Universitat Autònoma de Barcelona, 08193 Cerdanyola del Vallès, Spain Journal Magnetic Resonance Materials in Physics, Biology and MedicineOnline ISSN 1352-8661Print ISSN 0968-5243
MR perfusion imaging by alternate slab width inversion recovery arterial spin labeling (AIRASL): a technique with higher signal-to-noise ratio at 3.0 T
Fri, 13 Jan 2012 17:15:50 -0000
Abstract Object To propose a new arterial spin labeling (ASL) perfusion-imaging method (alternate slab width inversion recovery ASL: AIRASL) that takes advantage of the qualities of 3.0 T. Materials and methods AIRASL utilizes alternate slab width IR pulses for labeling blood to obtain a higher signal-to-noise ratio (SNR). Numerical simulations were used to evaluate perfusion signals. In vivo studies were performed to show the feasibility of AIRASL on five healthy subjects. We performed a statistical analysis of the differences in perfusion SNR measurements between flow-sensitive alternating inversion recovery (FAIR) and AIRASL. Results In signal simulation, the signal obtained by AIRASL at 3.0 and 1.5 T was 1.14 and 0.85%, respectively, whereas the signal obtained by FAIR at 3.0 and 1.5 T was 0.57 and 0.47%, respectively. In an in vivo study, the SNR of FAIR (3.0 T) and FAIR (1.5 T) were 1.73 ± 0.49 and 1.02 ± 0.20, respectively, whereas the SNRs of AIRASL (3.0 T) and AIRASL (1.5 T) were 3.93 ± 1.65 and 1.34 ± 0.31, respectively. SNR in AIRASL at 3.0 T was significantly greater than that in FAIR at 3.0 T. Conclusion The most significant potential advantage of AIRASL is its high SNR, which takes advantage of the qualities of 3.0 T. This sequence can be easily applied in the clinical setting and will enable ASL to become more relevant for clinical application. Content Type Journal ArticleCategory Research ArticlePages 1-9DOI 10.1007/s10334-011-0301-8Authors Yasuhiro Fujiwara, Radiological Center, University of Fukui Hospital, Fukui, JapanHirohiko Kimura, Department of Radiology, Faculty of Medical Science, University of Fukui, 23-3, Shimoaizuki, Matsuoka, Eiheiji-tyo, Yoshida-gun, Fukui, 910-1193 JapanTosiaki Miyati, Division of Health Sciences, Kanazawa University Graduate School of Medical Science, Kanazawa, JapanHiroyuki Kabasawa, Applied Science Laboratory Japan, GE Healthcare Japan Corporation, Tokyo, JapanTsuyoshi Matsuda, Advanced Application Center, GE Healthcare Japan Corporation, Tokyo, JapanYoshiyuki Ishimori, Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, Ibaraki, JapanIsao Yamaguchi, Department of Radiological Technology, Osaka Butsuryo College, Osaka, JapanToshiki Adachi, Radiological Center, University of Fukui Hospital, Fukui, Japan Journal Magnetic Resonance Materials in Physics, Biology and MedicineOnline ISSN 1352-8661Print ISSN 0968-5243
Repeatability of renal arterial spin labelling MRI in healthy subjects
Fri, 13 Jan 2012 17:15:46 -0000
Abstract Object Arterial spin labelling (ASL) can be used to measure renal perfusion non-invasively. The aim of this study was to determine the repeatability of this technique in healthy kidneys to vindicate its use in clinic. Materials and methods Two groups of healthy volunteers were imaged two different days to assess intra- and inter-session repeatability. Oblique-coronal data volumes were acquired on a 1.5 T scanner with a dedicated abdominal 32-channel body phased array coil. ASL was performed using a multi-TI FAIR labelling scheme and 3D GRASE imaging module. Background suppression and respiratory triggering were used. T1 maps of the kidney were acquired using the same sequence with background suppression disabled. Results For the group with multiple intra-session ASL measurements, the average cortical perfusion was 197 mL min−1100 g−1 and average cortical T1 was 1265 ms. For both perfusion and T1 the variation shown by the within-subject standard deviation (SDws) (14.6 mL min−1100 g−1 and 33.4 ms) and coefficient of variation (CVws) (7.52 and 2.69%, respectively) was small for all the analyses carried out. Bland–Altman plots were also used to visualise the variation between the same parameters collected from the different scanning sessions in both groups, and demonstrated good reproducibility. Conclusion We have shown that in healthy volunteers, ASL parameters are repeatable over a short and long period. This supports the overall aim of using ASL in the clinic to assess longitudinal renal perfusion changes in patients. Content Type Journal ArticleCategory Research ArticlePages 1-9DOI 10.1007/s10334-011-0300-9Authors Marica Cutajar, Imaging and Biophysics Unit, UCL Institute of Child Health, 30 Guilford Street, London, WC1N 1EH UKDavid L. Thomas, Department of Brain Repair and Rehabilitation, UCL Institute of Neurology, Queen Square, London, WC1N 3BG UKTina Banks, Department of Radiology, Great Ormond Street Hospital, London, WC1N 3JH UKChristopher A. Clark, Imaging and Biophysics Unit, UCL Institute of Child Health, 30 Guilford Street, London, WC1N 1EH UKXavier Golay, Department of Brain Repair and Rehabilitation, UCL Institute of Neurology, Queen Square, London, WC1N 3BG UKIsky Gordon, Imaging and Biophysics Unit, UCL Institute of Child Health, 30 Guilford Street, London, WC1N 1EH UK Journal Magnetic Resonance Materials in Physics, Biology and MedicineOnline ISSN 1352-8661Print ISSN 0968-5243

Sites:
Brainscans.com: Brainscans.com offers a scheduling service for obtaining an MRI brainscan for $169. It is available to anyone 21 years or older without existing medical or health conditions that would be adversely affected by an MRI. As a result, for the first time members of the general public will be able to o...Cardiac MRI Anatomical Atlas: The Society of Cardiovascular Magnetic Resonance (SCMR) represents physicians, scientists, and technologists working in CMR. We are committed developing CMR through education, quality control, research, and training
Cognitive Engineering: Cognitive Engineering analyzes Functional MRI for forensic (truth deception interrogation and image recognition), pharmaceutical research and marketing studies, cognition, memory, thought, security
functional MRI (fMRI): functional MRI ( fMRI ) links and information
Hamilton-Smith Consultants: MRI Services
How Stuff Works: Magnetic Resonance Imaging (MRI): The biggest and most important component in an MRI system is the magnet; it’s so strong, it could suck a metal watch right off your wrist and into the machine. Find out about magnetic resonance imaging.
International MRI Accreditation Resources LLC: MRI ACR (American College of Radiology) accreditation, by MRI accreditation consultants. (San Francisco, CA)
International Society for Magnetic Resonance in Medicine: The ISMRM is a nonprofit professional association devoted to furthering the development and application of magnetic resonance techniques in medicine and biology.
Laboratory of Diagnostic Radiology Research: Clinical research in the imaging sciences within the areas of Magnetic Resonance Imaging, Magnetic Resonance Spectroscopy, Molecular Imaging, Image Processing as well as other areas of imaging sciences. (National Institute of Health)
Leeds Cardiac Magnetic Resonance, UK: Info on Leeds Cardiac Magnetic Resonance and educational Cardiac Courses.
Magnetic Resonance Technology Information Portal: Magnetic Resonance - Technology Information Portal (www.mr-tip.com) is a free web portal for magnetic resonance imaging. Radiologists, technicians, technologists, administrators, and industry professionals can find information about magnetic resonance basics, technology, artifacts, contrast agent...
Maryland Open MRI: Maryland Open MRI offices serving you ...
Max MR Imaging, Inc.: Provideing information about Max MR Imaging Inc., provider of shared diagnostic imaging, treatment and related management services through a combination of mobile and fixed-site MRI facilities.
MRI Net: Find a Nuclear Medicine, MRI(Magnetic Resonance Imaging ), PET, CATSCAN, or Ultrasound Facility in the United States. Search by zip code. FREE Listings, marketing, web hosting and web page design, PACS/RIS, DICOM, Patient information
MRI Practice: enter a description here
RadiologyInfo - Magnetic Resonance Imaging (MRI): Links to current and accurate information for patients about Magnetic Resonance Imaging (MRI) procedures.
Spine-Health: Do I need an MRI scan for my back pain or neck pain? By Spine-health
The Adelaide MR Website: A page of MRI resources and links maintained by a working MRI Radiographer
The Future of MRI and MRS: An abstract on the future trends of MRI and MRS authored by Andrew A. Maudsley Ph.D and Michael W. Weiner M.D.
The Hipax PC Archive System: The Hipax Medical Imaging and Communication System/Hipax is DIOCOM 3 multi modality image processing tool/PC Win95,98,NT4.0
